Francesco, Please try the attached and see if it works. It is an "overlay" preset (MCU emulation) that doesn't initialize (change) anything except the 4 banks of VPot encoders. I've attached both sysex and script. I'm also trying a version that includes .tx for the bank change messages as well as .easypar for the encoder itself - so as hopefully to be able to handle LED feedback from the DAW. In that regard, I wonder whether setting the .default encoder setting to 3 would work to get appropriate LED display, or would the action be more complicated or not possible at all? (Royce, any ideas on this?) Art Hunkins ----- Original Message ----- From: Francesco Cecconi To: bc2000@yahoogroups.com Sent: Wednesday, November 28, 2007 1:42 PM Subject: Re: [bc2000] Re: BCR Sysex from DAW Hey i thought you were on holiday! thanks for your work - i thought the rel2s, reloffs etc should have been used to produce a relative controller - in the meantime: -i noticed that the feedback messages for the Vpots are cc48-55, on channel 1, with the following values (linked to the graphical behaviour): 1-11 dot, 17-27 pan, 33-43 bar, 49-54 Q-style - i tried too to add notes in the .tx field to route the messages to the correct pages and it works - i'm having a look inside bcr 1.1firmware sysex...just to see if it's possible to recognize the strings related to MCU emulation (i'm not very optimistic) and especially the led beahviour (MCU has 11 leds, corrsponding to led 3-13 of the BCR) Take care, Francesco ----- Messaggio originale ----- Da: abhunkin <abhunkin@...> A: bc2000@yahoogroups.com Inviato: Mercoledì 28 novembre 2007, 18:37:25 Oggetto: [bc2000] Re: BCR Sysex from DAW Francesco, As Royce stated (way back on August 18 - message 533), Art's .easypar CC 1 16 0 127 relative-3 can be had with .tx $B0 16 ifp 1 ifn $41 This is the.tx code I'm working with for your multiple VPot sysex - but incorporating multiple page/bank -/+ messages at the beginning of the .tx. The ifp/ifn options are wonderful with encoders. Art Hunkins --- In bc2000@yahoogroups. com, "goyya76" <goyya76@... > wrote: > > Hi Royce, > > as you were saying the BCR seems to respond only to CC set up > in ..easypar - i could put the relative Vpot message (eg for Vpot1 CC 16 > ch 1, range 0-127, relative-3) but i don't know how to writethe .tx > string inserting a relative value (if it's possible, of course)... > > ciao, > > Francesco > ------------------------------------------------------------------------------ ------------------------------------------------------------------------------ L'email della prossima generazione? Puoi averla con la nuova Yahoo! Mail
Message
Re: [bc2000] Re: BCR Sysex from DAW
2007-11-29 by Art Hunkins
Attachments
- No local attachments were found for this message.