Re: Gate Sequencer Questions

2006-04-15 by sasami@hotkey.net.au

> "The following outputs are for internal use only, when connected to the
switch bank and output buffer boards: ODIS (output disable), CLK OUT (clock
out), C1 to C8 (column outputs). Do NOT bring these output out to front
panel jacks, as you may damage the circuitry. "

> Can I bring out the Column Outputs for stage outputs to the panel?

The column outputs marked as OP1-8 can be. The ones marked as C should not be.

> ...If bringing them out is their pulse length dependant on the switch
settings or are the like a simple pulse out with the same length each stage
regardless of the switch setting?

Their length is one full clock cycle.

> Can I bring out the clock through output to the panel?

Marked as Clock Out. Not directly. You would need to add a buffer.

> Can I bring out the ODIS and what exactly does it do if so?

No. It is for internal use only. Output Disable.

> Separately, do the full/mix outputs really = gate outputs with varying
gate length depending on the switches?

Yes.

> One last thing, can you mod something to cascade 1 set of switches to the
second set for 16 step lengths? Figure this one is a long shot.

Cascade two complete sets of boards together. Yes.

Ken

_______________________________________________________________________
Ken Stone sasami@... or sasami@...
Modular Synth PCBs for sale <http://www.blaze.net.au/~sasami/synth/>
Australian Miniature Horses & Ponies <http://www.blaze.net.au/~sasami/>

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.