Yahoo Groups archive

Cgs synth

Index last updated: 2026-04-28 23:16 UTC

Message

Re: Normalling 2 Analog Shift Registers and adding an attentuator

2008-05-08 by sasami@hotkey.net.au

>At the moment I think of wiring a 100k pot after the CV input. . While
>this is cool for some applications I wonder wether this knob will
>affect a quantized CV at the input in a way that it is no longer
>quantized at the output. What do you think?

It will mess up the quantized signal in the same way as the CV level pot
would on your VCOs. You really want the quantizer AFTER the ASR (and yes,
that would mean one per output).

>I think about normalling the 2 Shift Register for one with six stages.
>It's obvious that the Clock In 1 goes to the switch of the input jack
>of the Clock In 2. Could please s.o. confirm if it's ok to connect the
>Stage 3 Output of the first shift register to the switch of the input
>jack of the CV In of the second one?

It is perfectly okay to do so.

Ken
_______________________________________________________________________
Ken Stone sasami@...
Modular Synth PCBs for sale <http://www.cgs.synth.net/>
Australian Miniature Horses & Ponies <http://www.blaze.net.au/~sasami/>