Best of CGS Panel #3 Oscillator signal bleed problem

2011-10-17 by Stephen

Hi Ken and All

I built the Best of CGS Panel #3 last year and i have never been able to get rid of the signal bleed from the CGS 48 oscillators.

To describe what is happening : Even with nothing patched ; when i plug the panel's output into a mixer , even with the output turned all the way down , i can still hear the oscillators in the background regardless of whether i take my output signal from VCA's or from the Dual Mixer.

I am powering the panel with and elby all in one power module 30VA +/-15VDC.

I'm using a split output cable with the Earth coming off the Sleeve , Output signal is on the Tip. That Earth from the cable goes to a Banana Jack connected to the Power Module's main Earth Stud.

On the 15V side of the Power Module + , - and Earth is connected to the panel via CGS Distro which is insulated from the Chassis.

I have not taken any Earth Connection directly to the Chassis.

many thanks

Stephen