Re: CGS028 direction and reset questions

2016-04-06 by Ken Stone

Reverse switch/jack.
Usually, the input jack will over-ride the switch. Yours is working the other way around.
The Reverse switch/jack thing will be caused by one of two things:
1) what you are driving it with is a weak signal
2) You have the jack and switch inputs swapped with each other.


The reset issue is a build error. Look around the lone BC547, and the associated parts. Make sure nothing is in backwards.

On Wed, Apr 6, 2016 at 9:15 PM, philippe@... [cgs_synth] <cgs_synth@yahoogroups.com> wrote:

Hello,


I've built this and it works fine, excepted (perhaps) for 2 small issues :


- the direction jack only works if the direction switch is set to reverse

- the reset jack works fine in forward mode, but doesn't work when in reverse direction


Is it normal behaviour or do you think it comes from a build error ?


Thanks for your insight


Philippe




--