> From: sukhoy27@... > > I just complete to replace the membrane switch Panel , thanks > to Paul very detailed Photo instructions , and so my Polaris > model 301420 still play like new !!! > But probably because is has bend not working for 5/6 years > something happens and the panel slider from Master Volume to > the assignable control when moved works only 40% . The > sliders that has yo be in the centre working position works > only when moved down , but not moved up. So what's wrong with the bend? Did you do the lever calibration? That's LOWER FUNCTION, A, 7, then move both levers through their entire ranges, then press LOWER FUNCTION again. It's probably a good idea to do all the calibration procedures, if you can manage to follow them in English. Sometimes it's possible to take a slider apart, clean it, and put it back together successfully, but not always. It's easier just to replace it. John Leimseider had some available back in September. If he doesn't respond to your query on the mailing list, you could contact him directly at john.leimseider@.... But try doing all the calibrations first. -- Ciao, Paul D. DeRocco Paul mailto:pderocco@...
Message
RE: [chromapolaris] Slider front panel not working properly
2013-01-02 by Paul D. DeRocco
Attachments