> From: minimelisma > > Thanks, Paul. I finally found some free time and was able to > resolve the panel issue. I'm happy to report that the problem > was just a remnant of the old tail clogging the connector, as > you said. Didn't need to break out the multimeter for that! I > knew it wasn't your panels, but some stupid mistake on my > part that was to blame. In one way I'm glad I was right about there being some junk in the connector, but in another way I'm not, because it means I've got to explain to future customers that the job of replacing the panels might be a little more difficult in some cases. In the spare Polaris that I just set up for testing membrane panels, I had one connector that had a fragment of the old tail in it that I simply couldn't get out, and I had to replace the connector, which is an easy soldering job for me, but not for everyone. > On the other hand, I'm still having trouble resolving two > other unrelated issues: The mod/pitch levers still aren't > responding and the linear potentiometer Syntaur.com sent me > (the same as pictured on their site) to replace the > "assignable control" slider doesn't seem to match the old > component. It's not as wide, and the pinout doesn't match up. > Strange. The only thing I can think to do is rebuild the old > one using the internals from the new one. I'll let you guys > know if that works out, but I'm still clueless about the > mod/pitch issue. Seems like they should be functioning, as > they even still have their... springiness about them. I seem to recall that originally we used some larger sliders, more like the Chroma's, which had brass-colored metal casings and shafts. If you could measure the spacing of the mounting holes on the PC board, I could look through my old junk and see if I have anything that would line up with those holes. As to the levers not responding, the first thing to do, if you haven't already done it, is to do the lever cal, as shown on page 6-2 of the service manual. If that doesn't fix it, then measure the voltage on the wiper of each pot, and make sure that it is in the neighborhood of 2.5V at rest. If everything's at zero volts, then you've got a connector problem somewhere. If it's nonzero, but nowhere near 2.5V, then you may have a mechanical misadjustment, which you fix by loosening the nut and turning the body of the pot until you get around 2.5V in the center position. You'll have to pop out the springs to do this. > Also, my unit still has what I believe are the original > D-cell batteries? Matsushita brand? Remarkably, they're still > working, and show no signs of corrosion, but I just know that > they should be replaced at this point. Might as well put in new ones. The old ones may be approaching the point where the RAM might start dropping bits, even if it's not showing any corrosion. -- Ciao, Paul D. DeRocco Paul mailto:pderocco@...
Message
RE: [chromapolaris] Re: Left membrane panel woes
2013-08-15 by Paul D. DeRocco
Attachments
- No local attachments were found for this message.