On Jan 27, 2009, at 10:10:29 AM, "Nathan Gutman" wrote:
Using Spyder2Pro Studio, software version 2.3.5 in WinXP SP3.
When trying to calibrate my Viewsonic G810 at the end of the process I get this message:
"Sorry there was a problem calculating the correction curve for the monitor.
Error-2 (Gamma.cpp) 886"
I googled for solution and tried all that was suggested but no joy. Contacted the company's supposed tech support but no one is replying so it seem that their tech support is dead.
Does anyone know what this error means and what is the fix?
---
I assure you, the rumors of our death are much exaggerated (to paraphrase old Sam Clemens). Did you go to the website, and create a support ticket in the ticket system? Any other method is not contacting Datacolor technical support... if you did create a ticket, send me (me, not this list!) the ticket number, and I'll look it up for you.
--
C. David TobieWW Product Technology Manager
Digital Imaging & Home Theater
Datacolor
CDTobie@...
www.datacolor.com/spyder3