Re: Incorrect printer profile from SpyderPrinter

2012-07-25 by kk325ic

Thanks David for taking your time to help out.

> (As a rough guideline: for matte paper, the first patch in the target, which
> is "perfect" black, usually measures with an L value in the upper teens to
> the low 20's at most on matte papers. An L value above, say, 22 or 23 would
> be a warning sign that something else is wrong. 
I get the measured L value of the first patch about 17. If I adjust the L of the reference black point to 3 in the advanced edit, the softproof result looks much better. 

It seems to me that the measure of the black patch is not very accurate enough. If this is true, SpyderPrint should be able to automatically adjust the black reference point to get the best result.

> 
> If you'd like email me a copy of your measurement file and I'll take a quick
> look to see if there are any problems. Use the File:Open Data command in
> SpyderPRINT to open your measurement file folder; find the .xml file; then
> .zip and email it to me at dmiller@...
Yes, I sent you the measurement file.

Attachments