Eml synthesizers group photo

Yahoo Groups archive

Eml synthesizers

Index last updated: 2026-04-28 23:23 UTC

Message

External CV of EML101

2007-05-16 by Dan Levey

I'm a bit late on getting in on this but I have managed to play my 
101 by Midi with a bit crazy workaround but all external and needing 
a computer sequencer.

I found that the "External Osc Control" input is the only one that 
can control all 4 Osc's equally.  You have to turn the Control Knob 
all the way to the left as well.  The problem is, This input is not 
scaled for anywhere near 1 - 1.2v/Oct, it needs about 3 or more 
volts/oct to track correctly.  As a quick solution, I went into 
Cubase and set up a transform midi track to multiply any note I play 
by 3.2.  That makes the 101 track perfect with about a 2 octave range 
before midi notes run out.  I can play the 101 keyboard to set the 
octave ranges my midi will control.

Also, if you patch Gate into the External Env control, you will find 
that there is no ENV 1 External control input.  What I did is buy a 
Doepfer envelope and power connector and have that patched into the 
Filter CV so it triggers along with everything else.

Lots of work but it all works for me.

Dan
http://www.REwireMusic.com