Hi Guys, I went through the tuning section of the callbration procedure for the monopoly but ran into some issues. Everything went as expected (e.g. read and adjusted the expected voltages) but when it came to adjusting KLM-398 I found that VR-3 and VR-4 were having no effect on the tuning for OSC 3 and 4 respectively. OSC2 I was able to tune relative to OSC1 without a problem. On top of this, OSC 3 is very out of tune. Adjusting the tuning knob on the front panel to extreme values still will not put it into the right range. So a couple of questions: 1. Is it possible that the TL072 which is attached to VR3 and VR4 of the KLM398 is dead? 2. AT the end of step 3 in the callibration procedure I am supposed to adjust VR101, VR102, VR103, and VR104. I am assuming these are on the other side of the PCB so I need to detach it from the front panel (e.g. undo all the knobs and pull the pcb out) just to be able to access the oscilator tuning? 3. At the beginning of step 3 it says to check the lead wires connection points and make sure the DC offset is +/- 0.1mV. Is this voltage measurement relative to each oscilator? I was not clear on what actual votlage (e.g. between what points) I am reading. Your help is appreciated! btw, I fixed that previous problem of the bad main output. It turned out to be a problem with my patchbay!!(should have done better signal chain trouble shooting)