Hello > Anyways, now what I found is that if I'm using the arpeggiator > clocked by MG2 and the sample and hold clocked by MG2, the sample and > hold is lagging. I think the S/H circuit is looking for a positive > going trigger while MG2 is spitting out a negative going trigger. I > could make a little trigger converter in my circuit to fix this. > Anyone have any opinions or experience with this? It is not the MG2. It is the Arpeggiator: the arpeggiator clock-in is a "switched trigger" and - if fed with a voltage clock - clocks on the negative edge. You find a instruction for the modification on http://fa.utfs.org/diy/korg_monopoly/modifications.html look for: "V-Trigger to S-Trigger Adapter for the Arpeggio Clock" Florian -- http://fa.utfs.org/
Message
Re: [korg_mono-poly] Sample and hold clock trigger
2012-04-20 by Florian Anwander