For a more complete listing I came across this for Jeep using search string "J1850 MESSAGES". This got loads more hits than other efforts. http://www.stu-offroad.com/engine/scancodes.htm Cheers Al Onestone wrote: >This gleaned from agoogle for J1850 COMMANDS. tHE 808 MENTIONED IS A >gENERAL mOTORS hOLDEN (aUSTRALIAN) vehicle. > >maybe this will be of some help. > >Cheers > >Al > > > >>Bruce >>The fault code 22 you saw was TPS voltage too low. >>My manual says that this code is set if TPS voltage falls below 0.15V >> >>Here is a list of all 808 Fault codes. >> >>12 System Functioning OK >>13 Oxygen sensor Open Circuit >>14 CTS low ( <0.7V) >>15 CTS High (>4.65) >>21 TPS High (>2.5V and MAP <60kPa fot 2 secs) >>22 TPS Low (<0.15V) >>23 MAT High (>4.9V) >>24 VSS Error >>25 MAT Low (<0.3V) >>33 MAP High >>34 MAP Low >>41 No Refrence Pulse >>42 EST Failure >>43 Knock Sensor open or shorted >>44 Oxygen sensor low (<0.25V, >20Sec) >>45 Oxygen sensor high (>0.45V, >20Sec) >>51 MEMCAL Error >>55 A to D error (>5.5V) >> >>Hope that this helps >>Cheers >>Matt >> >> > > > >Greg Deuerling wrote: > > > >>>-----Original Message----- >>>From: lpc2000@yahoogroups.com [mailto:lpc2000@yahoogroups.com] On Behalf >>>Of Randy M. Dumse >>>Sent: Friday, January 06, 2006 3:37 PM >>>To: lpc2000@yahoogroups.com >>>Subject: RE: [lpc2000] Re: J1939 stacks for the LPC2xxx's? >>> >>> >>> >>> >>> >>>>Do you know anything about J1850 (OBDII)? >>>> >>>> >>>> >>>> >>>What do you need to know? I've done keyword protocol. >>> >>>Randy >>>www.newmicros.com >>> >>> >>> >>> >>I'm a "me too" on this topic :) >> >>Is there any documentation out there on how to get info from an OBDII port? >>I had a OBDII scanner hooked up to a Ford truck at one time and was able to >>figure out a few commands like oil temp, tran temp, ... It would be nice if >>there was a document that covered all of the commands. I've Googled quite a >>bit on the subject and have come up with nothing. >> >>Thanks for any info you could give out!!! >> >> >>Greg Deuerling >> >> >> >> >> >>>-----Original Message----- >>>From: lpc2000@yahoogroups.com [mailto:lpc2000@yahoogroups.com] On Behalf >>>Of Randy M. Dumse >>>Sent: Friday, January 06, 2006 3:37 PM >>>To: lpc2000@yahoogroups.com >>>Subject: RE: [lpc2000] Re: J1939 stacks for the LPC2xxx's? >>> >>> >>> >>> >>> >>>>Do you know anything about J1850 (OBDII)? >>>> >>>> >>>> >>>> >>>What do you need to know? I've done keyword protocol. >>> >>>Randy >>>www.newmicros.com >>> >>> >>> >>> >>> >>>Yahoo! Groups Links >>> >>> >>> >>> >>> >>> >>> >>> >>> >>> >> >> >> >> >>Yahoo! Groups Links >> >> >> >> >> >> >> >> >> >> >> >> > > > > >Yahoo! Groups Links > > > > > > > > > >
Message
Re: [lpc2000] Re: J1939 stacks for the LPC2xxx's?
2006-01-06 by Onestone
Attachments
- No local attachments were found for this message.