> Hi , > Would anybody know if AGA-3 AGA-8 calculation is duable on LPC214X ? > And possibly where can AGA-3/8 source ANSI C be found . > Thanks Radim. I had to look up the definitions: Calculation for gas flow through an orifice meter (AGA3 calculation). The AGA3 calculations conform to methods described in American Gas Association Report No. 3, Orifice Metering of Natural Gas and Other Related Hydrocarbon Fluids. The calculation method is 1992 AGA3, with AGA8 compressibility methods (Detail, Gross I, or Gross II). The AGA8 methods calculate the compressibility factor based on the physical chemistry of the component gasses at specified temperatures and pressures. Expensive code: http://www.aga.org/Template.cfm?Section=Browse_by_Topic&template=/Ecommerce/ ProductDisplay.cfm&ProductID=162 http://www.starlingassoc.com/goflibc.htm The above two look pretty similar. Info: http://www.felib.com/fe_aga1992/feaga1992_0.htm Older version: aga8-85.zip 74313 09-22-96 AGA8 (1985) Supercompressibility Factors http://www.geocities.com/mymechboy/EngineeringSoftwareDatabase.htm Curious to what else you find. Joel
Message
RE: [lpc2000] AGA-3 AGA-8 on LPC214X
2006-03-09 by Joel Winarske
Attachments