Hi Kirsti Only bad experiences I'm afraid. We have purchased GreenHills Multi 2000 and the probe for a couple of projects but I have been trying to use it along with the LPC2106. We had to get a firmware update for the probe before it would reliably reset and run with the device, and now it has all been shipped off to GreenHills technical support in the states so that they can get the probe to work with breakpoints properly. Straightline code seems OK, but anything using interrupts causes breakpoints to be skipped, wrong addresses to be incremented, all sorts of fun. At the moment it is also not possible to use the probe to program the device flash. This means if you want to build and run from flash you have to use the Philips bootloader to program the flash, then reconnect the probe and start debugging with the hardware breakpoint. We first received the kit before Christmas and still haven't had it back again. We are not happy bunnies. If you or anyone else do get it to work reliably please drop a note into the group. We would be very grateful for any news, as at the moment we are at a dead end. Cheers Simon -----Original Message----- --- In lpc2000@yahoogroups.com, kiaa@n... wrote: > Hello group! > > I am working on a design with LPC2114 and I want to use the MULTI > development environment for > the device. <snip!> > - Does anybody have any experience with the LPC2000 and MULTI environment? > > Best regards > Kirsti