Timer interrupts on LPC2138

2006-05-13 by ylavoie66

Has anyone ever experienced a similar problem with timers on the 
LPC2138?

I want to get a timer to generate an interrupt at every 1ms (system 
tick).  I configured the prescaler so the timer would count with a 1ms 
period, and the match register set so the timer would generate an 
interrupt every 1ms.

This resulted in a 2ms system tick ??!!

As a test, I changed my prescaler, so the counter would count on a 1us 
period, and interrupt every 1000us, which is the same as 1mm here in  
Canada :)

I am still waiting for an answer from Philips, but it seems that 
setting a match of "1" is not working properly...