Hi all, I wanted to confirm the following operation of the LPC2124 on bootup. 1. The current Philips LPC2124 bootloader is Philips proprietary - Please confirm 2. Bootloader operation - Can you please confirm my interpretation of the power on reset and bootloader action (This is what I have interpreted from the LPC2124 User Manual) -Bootloader lives in the highest part of flash memory (8k size) -On Reset.... The bootloader is remapped to the top of a 2Gbyte boundary -64 bytes of the bootloader vectors are mapped in to 0x00000000 to 0x0000003f (the original interupt vectors). -The bootloader is always mapped in to the same location (top of 2Gbyte) so, execution of bootloader address is always fixed. -LPC2124 executes the first instruction at 0x00000000 jumps to a fixed address in the remapped 8k bootloader at the top of 2Gbyte. -bootloader code executes and looks for a low on P0.14. . ..... etc.... then follow the bootloader flow charts in the user manuals. 3. Please confirm the bootloader s/w checks the status of P0.14 and is not a fixed as a hardware test. Does my executive summary of the start up of the boot loader seem feasable? Thanks. Joe G
Message
LPC2124 Bootloader
2006-05-23 by phlpcmicro
Attachments