Re: Bootloader: Wrong answer on Prepare-Command (2) (Sector 2) CMD_SUCCESS

2004-04-01 by Andreas Schwarz

Robert Adsett wrote:
> At 06:41 PM 4/1/04 +0000, you wrote:
>>Hello,
>>
>>I'm using lpc21isp to program my LPC2106. When I try to download the
>>test2 hex file from the Aeolus newlib example, I get the following output:
>>
>>(...)
>>Writing Sector 0: ....(...)
>>Sector 0 written
>>Writing Sector 1: ....(...)
>>Sector 1 written
>>Writing Sector 2: ....(...)...Wrong answer on Prepare-Command (2) (Sector 2)
>>CMD_SUCCESS
>>
>>...and the program doesn't work (no traffic on TXD). If I change "#if 1" to
>>"#if 0" and vice-versa (to disable the UART echo example), the program loads
>>ok, and I can receive the "hello world"-message over the UART.
>>
>>What's wrong here?
> 
> Can you run the Philips ISP program? If so, does it work?

I just tried it, works perfectly.