Hello Bob, Thank you for your input. What you have reported here is a "documentation bug". While editing source documents, wrong text was entered. The right wording in the LPC2114 User Manual (February 03, 2004 revision), table 121 on page 162, "Capture Signals " section should be: " Capture functionality can be selected from a number of pins. When more than one pin is selected for a Capture input on a single TIMER0/1 channel, the pin with the lowest Port number is used. If for example in case of LPC2114 pins 30 (P0.6) and 46 (P0.16) are selected for CAP0.2, only pin 30 will be used by TIMER0 to perform CAP0.2 function." It is the same case with the LPC2119 and other CAN based LPC200 parts. Few days ago an updated revision of User Manuals for all 64 and 144 pin LPC2000 parts have been submitted for publishing to Philips web team and these documents are unfortunately going to be released without the input on capture functionality. However, the revision that will follow later on will have this included. Regards, Philips Apps Team --- In lpc2000@yahoogroups.com, "bobbruce000" <bobbruce000@y...> wrote: > On the LPC2114, multiple pins can be assigned to a single > capture port. For instance, capture channel 0 of timer0 > can be triggered by P0.2, P0.22 or P0.30. > > According to the manual, these triggers should work in > parallel, so a capture interrupt will be triggered from > any of them. But I can't get that to work. I only > get interrupts from the lowest enabled trigger. So > if I enable P0.30 as a capture trigger it works fine. > But when I enable P0.2, then I no longer get interrupts > when there is a trigger on P0.30. > > Has anyone else seen similar behavior? > > -bob
Message
Re: Using multiple capture pins
2004-05-07 by philips_apps
Attachments
- No local attachments were found for this message.