Hi Shannon. Thanks for your reply ! I dont think I'll use the CP2101's control pins (you'd probertly never know if an interfacing application would drive them) :) But many thanks for the suggestion ! Regards Lasse -----Oprindelig meddelelse----- Fra: Shannon Holland [mailto:holland@...] Sendt: 1. juli 2004 17:40 Til: lpc2000@yahoogroups.com Emne: Re: [lpc2000] Flash access & bootloader question ? On Jul 1, 2004, at 2:04 AM, Lasse Madsen wrote: > The Bootloader uses UART without the modem interface, can i connect > this > uart to a Cygnal CP2101 seriel to USB converter > (this device only has a 512 byte buffer as far as i remember so what i > dont > know is if the bootloader waits for some > character and then resumes operation like XON/XOFF sw flow control or > if it > just bursts all the data out ?) > I think if you read the flash section of the user manual you will find the answers to your questions. There is a response from the bootloader for each section of flash image you download so flow control should not be a problem. To get into bootloader mode though you need to hold P0.14 low at reset. So you either need GPIO and serial from your usb->serial converter or have some other way to hold that line low. If you can drive some of the modem control lines on the CP2101 then you could have it manage reset and P0.14. Shannon Yahoo! Groups Links
Message
SV: [lpc2000] Flash access & bootloader question ?
2004-07-02 by Lasse Madsen
Attachments
- No local attachments were found for this message.