Re: Secondary JTAG activation fails (ARM7, Olimex-Board)

2005-01-01 by sig5534

Most programmers and debuggers are responsible for calculating the 
signature word and putting it into the flash.  The Philips flash 
programmer certainly does this as does my Signum JetJTAG.  If your 
programmer does not, then you will need to calc it yourself. I think 
that is covered in the LPC210x manual.

Chris.