RE: [lpc2000] SPI on LPC2106

2005-02-25 by Ronnie Leighty

Hi Mark,

	I am having similar issue with the 2119 part where I noticed your PINSEL0
setting of 0x00000050 is misaligned with p78 or P127 of the 2119 user
manual. I'm I reading the table incorrectly? I register the value of
0x00001505 to have SPI 0 and UART 0 selected. But hey, mine is not
working...

Help anyone??

Regards

Ronnie Leighty
Principle Engineer
2802 Leslie Rd
Tampa, FL 33619
voice (813) 630-1229 ext. 111
fax     (813) 630-2619


-----Original Message-----
From: Mark Butcher [mailto:M_J_Butcher@...]
Sent: Wednesday, February 23, 2005 12:07 PM
To: lpc2000@yahoogroups.com
Subject: [lpc2000] SPI on LPC2106




Hi All

Just a quick question about SPI.

Today I tried to use it for the first time but had no luck. Possibly
someone has a tip.

Here's what I am doing:
1. Set SPI ports for SPI operation
     *(unsigned long*)*0xe002C000 |= 0x00000050 // PINSEL0
2. Setup SPI speed
     *(unsigned long*)*0xe002000C = 0x00000020  // SPCCR
3. Setup SPI to master mode
     *(unsigned long*)*0xe0020000 |= 0x00000020  // SPCCR
4. Send a test byte
     *(unsigned long*)*0xe0020008 = 0x00000055  // SPDR

After the last command the status register has the bit 0x80 (SPIF)
set to 1, indicating that the transfer has completed (before it was
at 0), but I see no data sent (neither signals on the clock line nor
the data line nor the SSEL line). In fact they all seem to be in a
high impedence state since I measure zero voltage (or 3V3 with a
pull up resistor).

Therefore I conclude that I have problems setting the SPI ports to
the correct mode but PINSEL0 seems to be correct (which I have
verified several times to be sure).

So what is the trick involved to get it working?

Thanks in advance

regards

Mark Butcher

www.mjbc.ch