--- In lpc2000@yahoogroups.com, "peterburdine" <lordofdawn@h...> wrote: > > --- In lpc2000@yahoogroups.com, "zvonkobharije" <zvonko@h...> wrote: > > > > hello > > > > i have a question regarding timer reset in lpc2138. (pclk = clk / 4) > > > > then I want to reset timer and I set T0TCR = 1. > > when I want to start timer again, I have to set T0TCR to 0 - do I have > > to wait for pclk or can I set T0TCR = 0 immediately? > > > > thx > > Zvonko > > I think you may be reading it wrong. > > To Reset > T0TCR = 0x2; > > To Start > T0TCR = 0x1; > > The numbers in the columns are the bit numbers, not values. damn... yeah, you're right. I feel very embarassed... :( ok, again: if I reset timer (T0TCR = 0x2) and then start it again (T0TCR = 0x1), do I have to wait for pclk before I set T0TCR to 0x1 or not?