At 06:51 PM 3/14/05 -0500, k b shah \(lascaux\) wrote:
>I  have check reset signal going to CPU --- it does not go to '0' state 
>i.e. it changes its level  from 3V  -- Normally high to 2V and then back 
>to 3V...

That sounds like a hardware fault.  Either with the board or the 
J-link.  It's acting as if the reset from the J-link is trying to pull it 
down but can't sink enough current.  Either the pullup on the reset is too 
strong or the reset on the J-Link is not able to sink reasonable current or 
there's a bad ground connection or ....

Robert