Hello, I have spend some time in getting the ADC on the move. The users manual states on page 198 that the ADC inputs are always connected to the I/O pins of the LPC. This is NOT correct. You DO HAVE TO use the PINSEL registers to connect the ADC inputs with the I/O connections. My users manual is release November 22 2004. If there is a more recent manual, please tell me where to find it.
Message
Error in LPC213x users manual
2005-06-20 by rggmns