Hello --- In lpc2000@yahoogroups.com, Ian Wraith <i.wraith@s...> wrote: > There are no problems initialising the CS8900 and I can even read > its EISA company ID correctly. I have just double checked this and it seems I can't read the company ID correctly after all. When I check this my program returns a value of 0x6355 where as the actual value should be 0x630E. So I can read the first byte correctly but the lower one is always 0x55 (an alternating pattern of 0's and 1's). My problem therefore is in the code that reads a word from the CS8900. My apologies for wasting peoples time. Regards Ian