--- In lpc2000@yahoogroups.com, Greg Deuerling <egads@f...> wrote: > Try setting the RBLE (bit 10) high in the BCFGx register. I was > seeing the exact same behavior and this got it going. I did and it generates the we signal when an access is made to external Flash memory. The text in the manual should be different : RBLE set = WE signal enabled RBLE cleared = WE signal disabled The bls signals are active no matter the rble setting. This might have something to do with the MW bits. > From my understanding of the > description of this bit setting it low should have been correct > for an 8-bit bus ??? Or byte wide devices on a word or double word data bus. I think the text is confusing. > Anyways, give it a try! I did :-) Now I have to fix the actual writing to memory : the we signal is present but nothing (apparantly) is written into the Flash. Thank you. roelof