1) Be sure diodes D1 and D2 are in the right orientation. 2) Be sure there is +5V on both ends of ferrite L3. 3) Be sure you have 100pf caps in C26 and C23, NOT 104s (0.1uf) Paul S. ----- Original Message ----- From: "gooboworks" <andy@...> To: <motm@yahoogroups.com> Sent: Sunday, January 27, 2002 1:44 PM Subject: [motm] MOTM 300 problem > I just completed my second 300 Oscillator. It appears that > everything works fine except the Sine and Triangle have no output. > The Saw and Pulse work fine. > > Any suggestions as to where I should look? I have checked over the > board, things look fine. The output for the Sine and Tri are just > completely dead. I have not checked any voltages anywhere yet. > > Please send any suggestions, I am not a EE, I do have a DVM, I do not > have a scope. > > Thanks > Andy Miller > > > > > > > > Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/ > >
Message
Re: [motm] MOTM 300 problem
2002-01-27 by Paul Schreiber
Attachments