2008-02-04 by Jason Proctor

please can the new S&H trigger on the rising edge of the clock? the 
falling edge trigger on the 101 made sync with other modules hard.

tx




>The input range is -6V to +6V (to have some headroom for +-5V signals, and
>to record some CVs not associated with standard waveforms). So, that is
>12v/16384 or 734uV per LSB. 'Perfect' 1 cent error is 833uV per LSB. My
>experience is that commercial MIDI-CV converters (not the '640, of course)
>and CV outputs of analog synths are accurate to ~1mv for each note. So the
>'102 has sufficient specs.
>
>The MOTM-650 has 150uV per LSB error :)
>
>Paul S.