Andy, 367 - The P6 is setup as shown in Fig 1 of the service manual. I have complete both the P/S adjustment which was slightly off before. And step (1) of which I had an issue but was able to get the LEDS to go from just A and 1 to all of them lighting up using the 56k res and adjusting VR1. after removing the 56k just A and 1 remained on. I did have some wrong components installed original including R2 which is now correct and original part from old board. I just did a test with my DVM and in a previous post you stated that the voltage should be 3.9v with the 56k in place. I am registering a 4.6v on the right side of R2. 369 - yes it is a lone blue wire. So was the cut trace between D1 and J2 intentional? If so where does the lone blue wire terminate? I understand it should be along the +5v rail just was trying to locate where it was soldered to before it came loose. Thanks in advance! Daniel --- In PolySix@yahoogroups.com, Andrew Jury <andy@...> wrote: > > Hi, > > First off, make sure you have the top panel controls set as in section 8, > figure 1 of the service manual. If the controls are set to anything other > else then the D/A settings will be wrong/unobtainable. > > Is the connection you mentioned in the power supply not just the additional > 5v rail which drives the MG LED? This would have the lone blue wire > connected to it at some point. > > Cheers, > Andy > >