Hi Robert, Are you repairing a board that has been acid damaged? That is an awful lot of silicon to be changing in one go! If you can¹t set up the reset circuit properly and just get a permanent active low in test mode then try replacing zener diode D2. As far the switches being in trouble do check the operation of the quad latches IC28/29/34/35. Moreover make sure there is a pulse train at the clock pin (5). If this board has had an acid spill then the lines back to P24/25 on the CPU are prone to becoming disconnected as they run under where the battery used to be! Cheers, Andy On 23/02/2011 17:57, "robobob66" <robertleiner@gmail.com> wrote: > > > > > > Hello list. > > I'm working on a broken KLM367 where i so far have put new logic > on IC 30, 31, 24, 26, 28, 29, 34, 35. > > When i test the reset circuit with a 56kohm dummy all the leds light up but > won't change when i adjust VR1. It only changes when i remove the dummy and > adjust on VR1.? > > The polysix makes sound and all pots works except all the switches on KLM 369 > dont work. The sound it self sounds like its being modulated by an fast lfo > that wont go away and it's not from the polysix lfo! bad A/D?. > > Ok, any light on this matter is help full! > > /Robert Leiner > > [Non-text portions of this message have been removed]
Message
Re: [PolySix] KLM367 problem
2011-02-23 by Andrew Jury
Attachments