2012-06-24 by tuk88@rocketmail.com

Wow ! Thank's a lot ! Everything work fine !

Just cause a noobie mistake...

The 10p give more stability, that's right ;)

Thank's a lot !


--- In PolySix@yahoogroups.com, "backshall1" <backshall1@...> wrote:
>
> And 10p for C23 on the clone boards seems to work better for clock
> stability.
> 
> Don B.
> 
>  
> 
>   _____  
> 
> From: backshall1 [mailto:backshall1@...] 
> Sent: Friday, June 22, 2012 5:14 PM
> To: 'PolySix@yahoogroups.com'
> Subject: RE: [PolySix] Re: Problems KLM-367 clone
> 
>  
> 
>  
> 
> I noticed the "Test" switch is in backwards, so when you move the switches
> towards "Norm", it will be in Test mode.
> 
> Don B.
> 
>  
> 
>   _____  
> 
> From: PolySix@yahoogroups.com [mailto:PolySix@yahoogroups.com] On Behalf Of
> tuk88@...
> Sent: Friday, June 22, 2012 3:40 PM
> To: PolySix@yahoogroups.com
> Subject: [PolySix] Re: Problems KLM-367 clone
> 
>  
> 
>   
> 
> Thank's for your answer !
> 
> @philippe.69 :
> 
> I'm french. I'll check your website ;) I fixed the 2 first bugs (regarding
> R98 and R52). What did you mean by : "Viewing ic 30.31, 21 can not be good"
> ? 
> 
> @backshall1 : I've got a 22pF capacitor. Here can you find some pictures :
> 
> http://imageshack.us/g/802/dscf1848t.jpg/
> 
> May it be possible for someone to give me a little functionnal schematic of
> the KLM-367 ? I really want to know how this board works.
> 
> 
> 
> 
> 
> [Non-text portions of this message have been removed]
>