Am using an original Korg Uk 240v txr. Does not get hot. ________________________________ From: Chromatest J. Pantsmaker<mailto:chromatest@azburners.org> Sent: 04/03/2014 05:18 To: PolySix@yahoogroups.com<mailto:PolySix@yahoogroups.com> Subject: Re: [PolySix] KLM376A1-PS delivering undervoltage at test points The transformer might be under-sized... so it can't provide enough current, so the voltage is dropping. Does the transformer get hot? On Mon, Mar 3, 2014 at 3:52 PM, tim p <target9@hotmail.com> wrote: > > > In my ongoing P6 power supply saga, have got UK transformer hooked up ok > but test points are reading > > +5 = 3.6 > +15 = 10.8 > -15 = -10.7 > > Is this likely a problem with the transformer or more likely the voltage > regulating components on the 376 board? Rectifiers shot? > > Have tried adjusting trimpots but that does not make result in a > noticeable voltage difference on the test points. > > Have tested the two main Caps and they are within tolerance. > > Any help or ideas appreciated. > > Cheers > > > > >
Message
RE: [PolySix] KLM376A1-PS delivering undervoltage at test points
2014-03-04 by tim p
Attachments
- No local attachments were found for this message.