Re: ARP Axxe question

2010-03-15 by Alexis V. Rogers

Hi Neil,

Digikey has a 4PDT switch that I've used to repair an ARP Axxe. The Digikey part number is SW106-ND. I don't remember if the pin spacing was exactly the same but I made it work.

Cheers,
Alex

--- In vintagesynthrepair@yahoogroups.com, Neil Boughey <neil.n.sheila@...> wrote:
>
> Nicolas
> 
> I had an Axxe with what sounds like the same problem (and what is a v.common problem on this synth). Check out the sustain and hold switch. If this has failed, due to the way these synths are wired, it permanently gates or "locks" the synth in sustain and hold "on" mode. 
> 
> The tech who fixed mine me advised me that a replacement 4 pole switch of the type ARP used on Axxes, Odysseys etc are virtually impossible to source, hence he rewired the synth to bypass the sustain and hold circuit which fixed the problem, You will have to live without sustain and hold in future, but worth it to fix one of these very nice little analogs. Otherwise, try a squirt of contact cleaner on this switch, between the plastic slider and the copper plating beneath, if you're lucky the switch might still be physically sound, although i'm advised the contact strips under the plastic assembly tend to corrode or fall off.
> 
> Let this be a lesson to anyone thinking of buying an ARP. Broken sliders are a relatively easy fix,  broken 4 pole switches are v.bad news, particularly on the Odyssey or Solus which use a few of these on the VCF and VCA sections.
> 
> Neil Boughey
> 
> neilnsheila@...
> 07590 114633
> 
> 
> 
> 
> 
> On 15 Mar 2010, at 19:05, Nicolas wrote:
> 
> > Hi everybody,
> > 
> > I just got an ARP Axxe and I'm wondering if there is something wrong with the VCA because the note that I play stays always on when I release the key on the keyboard.
> > Does anybody could tell me if this is normal with this synth?
> > Thank you!
> > 
> > Nicolas 
> > 
> >
>