I don't have any schematics, but I would: 1) check PSU delivers all the required voltages. Adjust if necessary. 2) check the control voltages driving the VCF when all sliders down; you should find 0V. If not, check who delivers a voltage. Might be a blown tantalum, a common disease on ARP. --- In vintagesynthrepair@yahoogroups.com, "Scott" <painintheamp@...> wrote: > > Hi... > > New to the shop > > Arp axxe 2310-631 > > OSC's are ok, Noise gen OK, S+H ok > > VCF ..Not so much... VCF Freq and ADSR only want to "work" at Max excursion of sliders. In some situations , Release , on the envelope gen > WONT release. > > I have a service manual. > > I'm a virgin to this unit so, be gentle. >
Message
Re: ARP Axxe..Issues
2012-06-08 by alesisfusion8hd
Attachments