Re: [vintagesynthrepair] CS-70m power supply issue, -15V rail is dead

2013-07-20 by Malte Rogacki

Ah, scratch that.

Different -15/+15V supply.

Anyway; the Trouble Shooting Guide in the service manual gives the
following procedure:

"5. No voltage is put out for -15V. Other voltage positions operate correctly."

"Probably cause: Tr21 - Tr20 - 0.22ohms.1P"

The service manual is here:

http://manuals.fdiskc.com/tree/Yamaha/