Re: [wiardgroup] Re: Any problems using the JAG with a 5 volt system (euro)?

2006-10-06 by damon

From Doepfer's technical page:

Control voltages, as produced by modulation s sources like the LFO  
and ADSR, are from -2.5 V to +2.5 V (5 VSS) for the LFO, and from 0 V  
to +8 V for the ADSR.

Plan B's envelope is +8v

Cwejman's envelopes are only +5v

Analogue Systems is like Wiard, 100m, etc.  However, not all Blacet  
is 10v.  The two Quad VCAs I've bought over the years have a 5v ceiling.

On Oct 6, 2006, at 11:20 AM, Grant Richter wrote:

> Why do you say the euro system is 5 volt?
>
> The standard set by the Arp 2600 is that all mini-jack systems  
> should be 10 volt control
> range systems. I know the following follow that: Wiard 300 and  
> 1200, All Blacet modules,
> PAIA 9700 modules, ARP 2500/2600, Roland 100 and 100m, Aries 3xx  
> modules.
>
> Did something get changed in the designs from european module makers?
>
> --- In wiardgroup@yahoogroups.com, "wiard300" <wiard300@...> wrote:
> >
> > I am considering buying a JAG to use with my "euro" modular. Are  
> there
> > any possible issues? I would probably run an LFO thru it, as an  
> example.
> >
> > thanks,
> > RSA
> >
>
>
>