Looks like an interesting module. I took a quick look at the sysex docs. It looks like you should be able to send both small and large dumps from the E-Mu. My experience is that small sysex commands can be sent on the fly. The only time I sent large amounts of data, I sequenced the data over time. (I used Cakewalk to sequence the banks of sysex data into a *.mid file and e-loader to put it in my E-Mu.) Single banks (400 bytes for performance dump; 608 bytes for voice dump; etc. [not including sysex header/eox]) should be no problem for the E-Mu to send. Best wishes with the project. --Steve --- In xl7@yahoogroups.com, Zsolt Szabó <Zsolt.Szabo@...> wrote: > > Hi Steve, > > yes, I want complete dumps to store in the patterns. > I asked the FS1R because the biggest sysex chunks originate from there, > very-very much parameters... > > Preferably I would send single banks data but multi is also > a must so larger chuncks are expected... > > I put up the FS1R documents on my ftp area. > The file you want to consult is fs1re2.pdf an look at MIDI implementation > at the end. > Now I'm in the process to completely remote the FS1R from my BitStream > MIDI controller so I use them frequently. > > ftp://pub:pub001@... > > > Thanks, > Zsolt
Message
Re: XL7 and in-pattern sysex storage
2006-08-26 by steve_the_composer
Attachments