Message

Re: E-loader Help

2009-04-11 by steve_the_composer

Update of e-loader "Get sequence" [transfer from E-Mu sequencer to computer] problem.
*If ID = 0, sequencer transfers.
*If ID > 0, transfer fails.
E-Mu sends songs packets 1 and 2 (universal system exclusive format).
e-loader (java console) reports a checksum error and sends NAK. 
It looks like the the actual cs = the "should be" cs + sysex ID.
(In snippet 1, ID was 64; in snippet 2 ID was 5; in snippet 3 ID was 1.) 

CONSOLE SNIPPET 1:
bad checksum received. packetNum: 0 cs was: 117 should be: 53
sending NAK

CONSOLE SNIPPET 2:
bad checksum received. packetNum: 0 cs was: 48 should be: 53
sending NAK

CONSOLE SNIPPET 3:
bad checksum received. packetNum: 0 cs was: 127 should be: 126
sending NAK
------------------------------

SUGGESTION:
If "Get sequence" transfer fails:
(1) check sysex ID [E-Mu sequencer and e-loader]
(2) check for bad checksum error in java console [e-loader]
(3) if "was" cs - "should be" cs = sysex ID, change ID to 0.

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.