Casio VZ1/10m Sysex Errata

The Casio VZ Sysex manual contains errors.

The following errors have all been confirmed by me,
by the close examination of the data which was necessary
when constructing my VZ patch editor
(see http://casio.sallyandsteve.com):

Page 8
======

III
1. Transmission format:
(1)  Please note that the HIGH order data is output first,
not the LOW order data.  The diagrams are not helpful as
it is not clear from them which is output first, but the
text is definitely wrong. This is a fundamental error.

Page 9
======
Bytes 1-4
The right hand column of the diagram should read, from
top to bottom, M1, M3, M5, M7.

Page 13
=======
Byte 317
The text should read: DELAY 00-63(H):0-99

Page 14
=======
Bytes 322-335
The last two bytes are not shown in the diagram (count
them!).  Bytes 334 AND 335 MUST both be set to an ASCII SPACE
character, value 32, otherwise the checksum will evaluate
incorrectly.

Page 21
=======
Byte 3
The bottom line of text should read: RELEASE 1:ENA, 0:DIS
(The values of 1 and 0 are stated incorrectly).


Steve Gutteridge
5th February 2005