This is a list of (hopefully) all triple output linear power supplies available from Mouser. All info transcribed without permission from the PDF files available at the given links. Errors excepted. I hope some kind and knowledgeable person will contribute info as to which units are best for use with the Buchla 200 (in terms of manufacturer and the ratio between the current at the 5V output vs the bipolar output pair). - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - INTERNATIONAL POWER: Case Inches +5V@A +-15V@A Price (US-$) AA 6.50 x 4.00 x 2.10 2 0.4 57.75 BAA 10.25 x 4.00 x 2.95 3 0.8 79.25 CC 9.38 x 4.87 x 3.28 3 3.0 122.25 D 9.00 x 4.87 x 3.28 6 1.0 94.50 CBB 11.00 x 4.87 x 3.28 6 1.5 104.95 131 11.00 x 4.87 x 3.20 8 1.5 125.95 DBB 14.25 x 4.87 x 3.38 12 1.5 141.50 DCC 15.00 x 4.88 x 4.55 12 3.0 162.50 Specifications: - AC Input: 100/120/220/230-240VAC, +10%-13%, 47 to 63Hz - Line Regulation: +/-0.05% for a 10% change - Load Regulation: +/-0.05% for a 50% load change - Output ripple: 5.0mV max peak-to-peak on 5-28V units Features: - UL, CUL, TUV, CE safety approved - Over voltage protection on 5V outputs (set @ 6.2+/-0.4V) - All chassis are pre-drilled to accomodate 597-P-12 and 597-P24 over voltage protection modules - Two year warranty Over voltage protection modules: 597-P12 $7.95 597-P24 14.66 Source: http://www.mouser.com//index.cfm?handler=fra_pdfset&dir=613&pdffile=763 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - CONDOR: Case Inches +5V@A +-15V@A Price (US-$) AA 6.50 x 4.00 x 1.80 2 0.4 59.97 BAA 10.25 x 4.00 x 2.50 3 0.8 82.90 CBB 11.00 x 4.88 x 2.75 3 3.0 111.21 D 9.00 x 4.88 x 2.75 6 0.8 98.19 CBB 11.00 x 4.88 x 2.75 6 1.5 113.31 NBB 11.00 x 4.88 x 2.75 8 1.5 130.95 DBB 14.25 x 4.88 x 2.75 12 1.5 147.33 DCC 15.00 x ???? x 3.75 12 3.0 169.17 Specifications: - AC Input: 100/120/240VAC: +10%, -13%; 215VAC: +12%, -11%; 47 to 63 Hz. Tolerance for 230 VAC operation +15%, -10%. Derate output current 10% for 50 Hz operation - Line Regulation: +/-0.05% for a 10% change - Load Regulation: +/-0.05% for a 50% load change - Temperature Rating: 0 to 50°C full rated; derated linearly to 40% at 70°C - Efficiency: 5V units: 45%; 15V units:55% Features: - World-wide AC Input ranges and safety standards - Burn-in with cycling; 3-year warranty - Transformer insulation meets Class F (155°C) - Exceed FCC & CISPR22 Class B conducted emissions - Approved to UL 1950, CSA 22.2 No 234 Level 3, and IEC 950 Source: http://www.mouser.com//index.cfm?handler=fra_pdfset&dir=613&pdffile=751 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -