-----Original Message----- From: 200e@yahoogroups.com [mailto:200e@yahoogroups.com] On Behalf Of cray5656 Sent: Saturday, December 20, 2008 2:05 AM To: 200e@yahoogroups.com Subject: [200e] 281e question >Why is it that out of the 3 momentary switches only the top one >transient, works without being plugged in? I assume you mean 'with no trigger plugged in'? The short answer is 'this is by design'. The middle position is transient - a rise followed by a fall upon receipt of a trigger. The top position is transient repeating, with no input trigger required (but a trigger input will still work). Hope this is clear and answers your question. Regard, Fred.