Yahoo Groups archive

200e

Index last updated: 2026-04-28 22:38 UTC

Message

Re: 200e MIDI

2008-03-27 by tmeade1974

So if you set the 250e to Advance mode and apply a pulse at the
Start/Advance input, the sequencer will advance to the next stage
every time it receives a pulse, regardless of any time setting you
have set.  I don't have it in front of me but that "should" be the
"default" setting on the 250e, ya?
--tom


--- In 200e@yahoogroups.com, "soma_studios" <john@...> wrote:
>
> Hey y'all,
> 
> Forgive the noob question, but I'm trying to get my head around the
250e stage selection 
> behavior... From what I gather below, it should be possible to
advance the sequencer one 
> stage per incoming clock pulse (assuming none of the
adv/sust/enble/stop functions are 
> selected for that stage), or no? It seems that whenever a pulse
arrives at start/adv, the 
> internal clock begins advancing as well...
> 
> Thanks much
> 
> John
> 
> 
> --- In 200e@yahoogroups.com, "ezra buchla" <ezra.buchla@> wrote:
> >
> > with midi, you can use the pulse outputs from the 225 note busses to
> > clock the 249e, 250e, or 291e in "advance" mode. i've used this a
> > lot... since each stage of each sequencer can be assigned logics w/r/t
> > incoming pulses, this allows for much richer behavior than just
> > syncing to a clock (which, again, we still plan to implement; the 249e
> > in particular already has a bpm data structure...).
> > 
> > you could also use an analog pulse as a clock. any voltage with a
> > (>=10v) -> (<10v) transition will work as long as the voltage source
> > and the 200e share a ground.
> > 
> > as for midi out, we're working on it and considering different
> > interface options. the strongest idea so far is to be able to
> > individually assign 225 busses to input or output CV, but this
> > requires some new GUI programmming. the wiring is all there already.
> > 
> > -eb
> > 
> > 
> > 
> > On 2/14/07, jon schatz <jon@> wrote:
> > >
> > >
> > >
> > >
> > >
> > >
> > > On Wed, 14 Feb 2007, ezra buchla wrote:
> > >
> > >  > since there's some speculation, hey
> > >  >
> > >  > neither 200e sequencers currently respond to midi clock, but
this is
> > >  > on the intended feature list for both. (i think that means the
> > >  > firmware is technically "alpha.") 249e firmware development
will be
> > >  > slower since there won't be any more of the hardware.
> > >  >
> > >  > MIDI out is another intended feature (the 225 is sired for it); i
> > >  > don't think any of us has specifically considered clock out
but it's a
> > >  > fine idea and it could be done if there's enough interest.
> > >
> > >  hi ezra/everyone,
> > >
> > >  how do you sync up your sequencers to external gear?
> > >
> > >  thanks,
> > >
> > >  -jon
> > >
> > >  "There are no differences but differences of degree between
different
> > > degrees
> > >  of difference and no difference."
> > >  - James, William. "Subjective Effects of Nitrous Oxide." Mind.
1882; Vol 7.
> > >
> >
>

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.