Yahoo Groups archive

68300

Index last updated: 2026-04-29 00:01 UTC

Message

RE: [68300] IRQ7 acting odd

2003-07-16 by Melear Charles-rdph40

Hello everyone,
 
Interrupt Acknowledgement Cycles always drive the address bus to $FF FFFx.  Programming the Base Address register to $FFF8 will give the address match.
 
The programming of the option register to $6B01 will make the SPACE field = 00 for CPU space, the IPL field = 000 for all interrupts, and AVEC = 1 for generate AVEC.
 
Regards,
 
Charlie

-----Original Message-----
From: Andrei Chichak [mailto:acpmiedm@...]
Sent: Wednesday, July 16, 2003 1:17 PM
To: 68300@yahoogroups.com
Subject: RE: [68300] IRQ7 acting odd


Okay, the programming of CS6 (as it happens, this was the next open CS) to 
the values that Brian Geery gave ("$FFF8 to CSBAR6 & $6B81 to CSOR6") 
actually worked. I am now getting my interrupt.

I suspect that there is a lot more information in the CSBAR fields that I 
will have to understand deeply. Right now this seems to be JPBM (just plain 
black magic).

Charlie, can you explain why this worked and how to properly configure a 
chip select for AVEC/DSACK generation?

Thanks again,
Andrei



Yahoo! Groups Sponsor	

ADVERTISEMENT
 <http://rd.yahoo.com/M=194081.3551198.4824677.1261774/D=egroupweb/S=1706554205:HM/A=1663535/R=0/SIG=11ps6rfef/*http://www.ediets.com/start.cfm?code=30504&media=atkins> click here	
  <http://us.adserver.yahoo.com/l?M=194081.3551198.4824677.1261774/D=egroupmail/S=:HM/A=1663535/rand=861798698> 	

---------------------------------------------------
To unsubscribe from this group, send an email to:
68300-unsubscribe@yahoogroups.com

To learn more about Motorola Microcontrollers, please visit
http://www.motorola.com/mcu <http://www.motorola.com/mcu> 



Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service <http://docs.yahoo.com/info/terms/> . 




[Non-text portions of this message have been removed]

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.