It depends on how the EEprom is configured, if the device is set to use a fixed serial number then it will always enumerate itself as the same com port whichever USB it is plugged into. I use these devices a fair bit and i always reconfigure the eeprom settings so that all FTDI devices (when i'm developing) will enumerate themselves as the same com port number. MPROG 3.5 can read write these settings or it can be done through the api dll. Regards --- On Wed, 24/2/10, enkitec@gmail.com <enkitec@gmail.com> wrote: From: enkitec@gmail.com <enkitec@gmail.com> Subject: Re: [AVR-Chat] Re: USB to serial db9 cable To: AVR-Chat@yahoogroups.com Date: Wednesday, 24 February, 2010, 12:35 On 24-Feb-10 02:06, Donald H wrote: > I have not found any USB-2-serial dongle that will keep the COMx number the same across USB ports. > > don > > I would like to introduce my FTDI USB-2-serial dongle that doesn't change the COMx number when connected on different USB port. Don't ask me why, I don't know. Mark Jordan [Non-text portions of this message have been removed]
Message
Re: [AVR-Chat] Re: USB to serial db9 cable
2010-02-24 by STEVEN HOLDER
Attachments
- No local attachments were found for this message.