Hi Steve! Many thanks for the infos! I just tried to send that VZcard09, but still getting the same message ( Load Error / Check system ! ). I don“t have used "deBug". (is this a freeware application?). So i am not sure about the midichanel within the datafile. here is what i did (used MidiOx): 02 MEM PROTECT - INTERNAL OFF 04 MIDI CHANNEL - I set it to "1" 05 MIDI DATA - ECLUSIVE enabled 03 LOAD - LOAD/SAVE > MIDI > [data type] > YES, YES As soon MidiOx starts to send the sysexdata, the VZ-10m gives me that error.... is there anything i am doing wrong? phono --- In CZsynth@yahoogroups.com, "steve_the_composer" <smw-mail@p...> wrote: > --- In CZsynth@yahoogroups.com, "phonophobie" <sidstation@h...> wrote: > > Last night i tried to send sysex banks from midiOX to my VZ10m too. > > I was getting an ERROR message all the time. ( vz said something > > about midi error/ Check system ). > > Here are the error messages I have been getting when sending VZ sysex > data to the VZ-8m. (See my previous message about channel and data > type matching.) > --------------------------------------------------------------- > Message: --TRANS ERROR--- | CHECK SYSTEM! > Problem: Data channel <> VZ receive channel > Solution: Change VZ channel to match sysex file data. > > Message: --MIDI ERROR--- | RECEIVE ERROR > Problem: Data type transmitted <> Data type expected > Solution: Select proper data type when loading data type into VZ. > --------------------------------------------------------------- > To see the channel and size of data, you can use debug [PC]. > > EXAMPLE [VZCard9.syx]: > F0 44 03 00 70 70 02 F7 > F0 = system exclusive data coming > 44 = Casio product ID > 03 = VZ line > 00 = VZ-1 format data [02 = VZ-8m format data] > 70 = channel 1 [7N where N = 0->F meaningchannels 1->16] > 70 = open communication > 02 = INT 64 voices + 64 op-mems > F7 = end of sysex transmission. > > F0 44 03 00 70 74 . . . [data] . . . F7 > 74 = data is coming next > > other codes for the 6th byte: > 71 = close > 72 = ok > 73 = error > --------------------------------------------------------------- > For the VZ-8m, I have the following SYSEX data sizes [received from > VZ]: > > 65661 = FULL [Voice + Op-Men + Total] > 65644 = VC+OP [Voice + Op-Mem] > 43094 = VOICE > 22672 = OPMEM > > The VZ files posted in files are 55958 which I assume is the VZ-1/VZ- > 10M VC+OP size. > --------------------------------------------------------------- > Hope this helps. > --Steve
Message
Re: VZ sysex bulk data transfers and error messages
2004-09-05 by phonophobie
Attachments
- No local attachments were found for this message.