Yahoo Groups archive

Casio CZ/ VZ/ FZ - Pro Series

Index last updated: 2026-04-28 22:42 UTC

Message

Re: [CZsynth] Re: CZ1000 RA-3 cartridge odd and even storage problem

2016-08-15 by SciFiArtMan

Amazing!


      From: "Daniel Forró danforcz@... [CZsynth]" <CZsynth@yahoogroups.com>
 To: CZsynth@yahoogroups.com
 Sent: Monday, August 15, 2016 9:35 AM
 Subject: Re: [CZsynth] Re: CZ1000 RA-3 cartridge odd and even storage problem

    Exactly what I have mentioned in my two messages from June 21st:
---------------
If it's not just some dirty contact, interrupted PCB line or similar mechanical problem...
---------------
Are you absolutely sure you followed all steps during the installation, and everything is well done, jumper desoldered and away from the instrument, traces cut properly, cables well soldered where they should be, no short circuit or something like this? 
---------------
Good to hear you could fix it.
Daniel Forro


On Aug 12, 2016, at 6:09 AM, quad303@... [CZsynth] wrote:


I managed to get the problem fixed. It was my own fault. DUH. During the battery backup install. I had cut an adjacent PCB track by accident.

Attachments