Dave Smith Instruments SYNTHESIZERS group photo

Yahoo Groups archive

Dave Smith Instruments SYNTHESIZERS

Index last updated: 2026-04-28 22:43 UTC

Message

Re: Remote SL 37/DSI PolyEvolver Rack sysex programming/map

2011-03-31 by justmullaya

I can confirm that indeed the Novation sysex is not comprehensive enough to support the evolver. I was also possibly the original uploader of the novation cc template 
It was 5 or 6 years ago when I tried but I seem to remember that the granularity with which the msb and lsb that the novation could specify was not sufficient.
Who to blame? God knows but since Dave Smith invented midi I'll bet on novation.
I also remember being thankful when the evolver got cc's though! 

--- In DSI_Evolver@yahoogroups.com, "jp" <jpazdan@...> wrote:
>
> I recently acquired a PER for live performance, and after considering the various midi controllers available, I decided on a Novation SL 37 as it sends sysex as well cc's etc, plays well, and I like the x/y pad. My goal in this was to have a 3 octave polyevolver, a 4 voice MEK as it were. To be able to use the x/y pad as a 4 way "vector" style mixer for the Osc's. To start the sequencer and use the SL's tap tempo pad..IOW, a slightly boosted controller that's specific to the PER.
> 
> Using the Novation editor, I was able to easily program in all the available cc's that DSI made available. But straight away, (the second set of controls actually, the Osc fine tune parameter)I had to start using sysex strings. I haven't used these, or thought about them, for years. Some brushing up via google re hex, binary etc and a copy of the PER midi specs later, I thought..no problem.
> 
> Try as I might I cannot get the PER to respond to what I think the proper configuration is. The post by James from 200? was very informative, but his method still didn't work. (another aside: I am not positive, but as it appears that you can input 2 different variables in the SL sysex string itself now, IOW, the lsb and msb can both be "dv" I assume his problem in that post was fixed. But..the Novation editor doesn't let you do this, it has to be done directly on the SL. i say "assume" because while it shows up in the screen on the SL..I still get no movement in the function on the PER)
> 
> There is the inherent problem here... I probably should be asking Novation about this, after all it is THEIR controller. But we all know what happens..one company throws the problem to the other..Novation says (even though their manuals and explanations seem not-so-complete)you will have to ask DSI..and though Tracy has been really helpful at DSI, he doesn't know how the SL works. So, I hope this forum might help.
> 
> I have asked on the Novation forum, also on the DSI forum, and haven't received any replies..none. I am therefore to assume I am the only person currently using a Novation SL remote to control an Evolver/PER through sysex. I know from reading the back posts here that isn't the case, but as in a lot of forums, people drop out after a while or move on to other gear and don't bother with the forums they once used. 
> 
> There is the one sysex template here, but it only covers the cc's.
> 
> Anybody?
>

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.