Re: hihat again......

2006-09-27 by Keith

--- In DTXpress@yahoogroups.com, Hans Meier <dronsb@...> wrote:
>
> Hello Keith,
> 
> I`ve measured the resistance today and I have the same
> values than you- but I`ll find it almost impossible to
> get the readings between 150k and 350k! I cannot hit
> and hold them even for a second, neither with my feet
> nor with my hand! The only value in between that I`m
> halfway capable of hitting an holding is the 350k,
> next will be eternity.
> Even stranger when you assume what the guy from
> drumtec told me (7 resistors...)?!
> I`ve also found another setting in the drumset overall
> parameters that is named HH sensitivity, played around
> with it but didn`t do much diference at all.

Wolfgang,

Unless someone else can shed any light on this problem, I would
suggest maybe you have a faulty HH controller.  I don't know how the
RHH works, but the HH pedal progressively shorts out the resistors to
give the final values (it actually consists of 150k, 10k, 47k & 150k
resistors in series).  Maybe you should return it as faulty?

Keith.