Re: [Digital BW] RE: 1400 won't recognize MIS Eboni- cartridges

2013-12-30 by Paul Roark

Paul,

My PA205 profile has an ink limit of 40 and a boost to 50. So, if your K-0-40 hit the dmax before the end, you'll have to make a new profile. I don't know why we'd be getting such different dmax points. Be sure you're measuring with at least a scanner -- not just eyeballing the dark end.

You might want to try taking my profile and just removing the boost, leaving the dmax at 40 and see how it prints. If, when you measure the relative densities, there is really no difference between 95% and 100%, you'll have to move the dmax down, clear the linearization tab values, and relinearize the profile with whatever new dmax value you've found. The "densities" in the profile will also be affected, but you may get lucky and not have to deal with them. You might, however, need to start over. If our printers are not behaving the same, there isn't much I can do on my printer to help. (And, of course, it leads one to wonder why they are behaving differently.)

Paul


On Mon, Dec 30, 2013 at 1:16 PM, <paulmwhiting@yahoo.com> wrote:

Been a while, I hope we can reconstruct the conversation here! Here's an extract from your last message to me, #35.

Paul W: I looked at a 21 step scale in a test print the next to last frame was indistinguishable from the very last frame (black). However there was clear delineation of all the steps at the lighter end, which speak for good highlight detail.
Paul R: You may need to check the dmax point -- K ink limit. You might notice that I have a curve in the Zip file (if not in QTR) called "K-0-100." This is a straight line curve that will test for the K ink limit with a 21-step test file without the need to waste an entire sheet of paper (as when Calibration mode is used just to see the K results). "If you're lucky the profile may have used a boost." If so, try putting in the new dmax there and re-saving the file. It might print well with no other changed needed.

Actually, what was in the zip file was K-0-40. I created the quad curve and printed the 21-step test file but its last several dark steps were all black. Then I created a quad file for K-0-100 and it was worse. So I went the other direction and created a K-0-20 quad file and this was better. So now do I back back to my 6 position file you created for me (PA 205) and lessen the black density? I think I know how to do that.

Also, in the quote above, I wonder if you would elaborate on the sentence I have in quotes there... thanks!

Best regards,

Paul